DFMHUB

Strike Pad ARK Make by DFMHUB | Structural Lightning Protection

Trusted experts in Earthing and Lightning Protection Systems since 2005.

Strike Pad ARK Make by DFMHUB Used in Structural Lightning Protection System

A Strike Pad is a critical protective component installed at the base of lightning down conductors or at high-risk impact zones of a structure. Its primary role is to absorb, distribute, and safely dissipate lightning strike energy, preventing direct damage to masonry, concrete, waterproofing layers, and architectural finishes.

The Strike Pad ARK Make by DFMHUB is specifically engineered for structural lightning protection systems used across India, where high lightning density, variable soil resistivity, monsoon-driven moisture ingress, and diverse construction practices demand robust, code-compliant solutions.

This page provides an engineering-led, standards-focused explanation of Strike Pads — covering design methodology, materials, testing, Indian use cases, and compliance — written for consultants, EPC contractors, electrical engineers, and infrastructure decision-makers.


Why Strike Pads Are Essential in Indian Lightning Protection Designs

India records one of the highest lightning strike densities globally, particularly in regions such as:

  • Maharashtra (Mumbai, Pune, Nagpur)

  • Telangana & Andhra Pradesh

  • Odisha & West Bengal

  • Karnataka & Kerala

  • NCR (Delhi, Noida, Gurugram)

In these conditions, lightning energy traveling through a down conductor can:

  • Cause concrete spalling

  • Crack masonry and plinth protection

  • Damage waterproofing membranes

  • Create dangerous step and touch potentials near ground level

A properly designed Strike Pad mitigates these risks by acting as a mechanical and thermal buffer at the most vulnerable interface between conductor and structure.


Designed & Manufactured for Indian Conditions

Strike Pad ARK Make by DFMHUB is not a generic imported accessory. It is designed, engineered, and manufactured in India, considering:

  • High ambient temperatures (45–50°C surface exposure)

  • Heavy monsoon rainfall and water stagnation

  • UV exposure on external walls

  • Mixed construction materials (RCC, AAC blocks, stone cladding)

  • Variable earthing resistance across Indian soil types

This ensures long-term reliability and lifecycle safety, even in aggressive environments.


Component-Wise Breakdown of Strike Pad ARK Make

ComponentMaterial SpecificationEngineering Function
Strike Plate BodyHigh-conductivity copper / copper alloyAbsorbs and spreads lightning impulse
Mounting BaseHeavy-duty insulating or metallic basePrevents direct masonry impact
Conductor InterfaceCompatible with flat/tape/round conductorsEnsures low-resistance continuity
FastenersSS / corrosion-resistant alloyLong-term mechanical stability
Surface FinishNatural copper / protective coatingWeather and corrosion resistance

Engineering Design Methodology

Step-by-Step Functional Design Logic

  1. Strike Interception Zone Identification
    Installed at locations where lightning current density peaks — typically near ground termination points.

  2. Energy Dispersion Principle
    The Strike Pad spreads the current over a larger surface area, reducing localized thermal stress.

  3. Mechanical Isolation
    Prevents direct conductor-to-concrete contact during high impulse events.

  4. Continuity Assurance
    Maintains uninterrupted electrical path between down conductor and earthing system.

  5. Durability Engineering
    Designed to survive repeated surge events without deformation or loosening.


Electrical Performance Characteristics

ParameterTypical Value
Peak Lightning Current HandlingAs per IEC 62305 (up to 200 kA)
Impulse WithstandHigh impulse current tolerance
Contact ResistanceExtremely low
Thermal StabilityMaintains integrity during surge heating
Mechanical LoadSuitable for exposed installations

Compliance with International & Indian Standards

Standards & Compliance Table

StandardDescriptionCompliance
IEC 62305Protection against lightning✔ Fully compliant
IEC 62561Lightning protection system components✔ Applicable
IS/IEC 62305Indian adoption of IEC✔ Followed
NBC IndiaStructural safety guidelines✔ Compatible

Typical Installation Locations

  • Base of down conductors at plinth level

  • External façade near ground termination

  • Industrial structures with exposed conductors

  • Rooftop-to-wall transition zones

  • High-rise building periphery


Installation Methodology (Consultant-Friendly)

  1. Verify down conductor routing and earthing layout

  2. Fix Strike Pad securely on prepared surface

  3. Ensure firm mechanical anchoring

  4. Connect down conductor with approved clamps

  5. Verify electrical continuity

  6. Record installation as part of LPS documentation


Industry-Wise Applications in India

Commercial Buildings

  • IT Parks in Bengaluru & Hyderabad

  • Corporate offices in Mumbai & NCR

Infrastructure & Utilities

  • Airports, metro stations, rail terminals

  • Power substations and control rooms

Industrial Facilities

  • Refineries, chemical plants, manufacturing units

  • Warehouses and logistics hubs

Residential & High-Rise

  • Luxury towers and gated communities

  • Hospitals and educational campuses


Manufacturer vs Trader: Why It Matters

AspectDFMHUB (Manufacturer)Generic Trader
Design Control✔ In-house engineering✖ None
Material Traceability✔ Yes✖ Limited
Customization✔ Project-specific✖ Standard only
Compliance Support✔ Full documentation✖ Not available
Long-Term Support✔ Yes✖ Transactional

Testing, Quality Control & Documentation

Each Strike Pad ARK Make by DFMHUB undergoes:

  • Material verification

  • Dimensional accuracy checks

  • Mechanical strength testing

  • Visual and finish inspection

Documentation Provided:

  • Product datasheet

  • Compliance declaration

  • Installation guidelines

  • Test reports (on request)


Services & Technical Support

  • Lightning risk assessment support

  • BOQ & tender assistance

  • Consultant submittals

  • Site installation guidance

  • After-sales technical support

📞 Request a technical consultation with DFMHUB engineers


Frequently Asked Questions (FAQs)

1. What is the main function of a strike pad?

To absorb and distribute lightning current safely, preventing structural damage.

2. Is a strike pad mandatory under IEC 62305?

It is recommended wherever down conductors interface with structures.

3. Can it be used with copper bonded or GI conductors?

Yes, ARK Make Strike Pads are compatible with standard conductors.

4. Is it suitable for coastal or high-corrosion areas?

Yes, material options are available for aggressive environments.

5. Where is it installed in a building?

Typically at the base of down conductors near ground level.

6. Does it reduce step and touch potential?

Yes, by controlling current dispersion.

7. Is it custom-manufacturable?

Yes, sizes and configurations can be customized.

8. Is documentation provided for consultants?

Complete technical and compliance documentation is available.

9. Is it suitable for retrofitting?

Yes, it can be installed in existing LPS systems