Lightning Protection Systems & Structural Earthing
Engineered to IS/IEC 62305.
DFMHUB manufactures, designs, installs and tests complete ARK Make - lightning protection and Structural earthing systems for Data centres, Sub Stations, high-rise towers and manufacturing facilities across India.
From Lightning Risk to Protection —
DFMHUB brings the entire chain under one roof from lightning risk assessment, system design and engineering to material supply, installation, testing and final documentation, we take end-to-end responsibility for the Earthing & Lightning protection system.
IS/IEC 62305 Risk Assessment
Evaluate the structure and determine the appropriate protection level through our ARK-Guard Tool.
System Design & Engineering
Develop lightning protection and earthing solutions aligned with applicable standards and project requirements.
In-House Manufacturing
ARK Make components produced and type-tested to IEC 62561 with batch traceability.
Installation & Commissioning
Execute installation with coordinated site-level responsibility.
Testing & Verification
Verify system performance through appropriate electrical continuity and mechanical checks.
Documentation & Test Reports
Deliver drawings, test reports and project documentation required for CIEG/Equivalent Approvals.

Lightning Protection Systems
Air termination mesh, down conductors, test points, and coordinated surge protection devices manufactured in-house to protect infrastructure against direct lightning strikes.

Structural Earthing Systems
Foundation rebar bonding, copper bonded rods, chemical earth electrodes, exothermic welding kits, and earth inspection chambers built for maximum longevity.
Standards we design and test against
IS/IEC 62305 (Parts 1-4)
Risk assessment, physical damage protection, and protection of electrical & electronic systems.
IS 3043:2018
Indian code of practice for earthing — electrode sizing, resistance limits and soil resistivity method.
IEC 62561 (Parts 1-7)
Type-testing of LPS components: connections, conductors, electrodes, enhancing compounds and test links.
NBC 2016, Part 8
National Building Code requirements for lightning protection of buildings in India.
IEC 61643 / IS 16571
Selection and coordination of surge protective devices for low-voltage systems.
NFPA 780 & NF C 17-102
International practice for LPS installation and early streamer emission terminals, where specified.

Send your drawings. Get a compliant system design back.
Share roof plans, structure height and soil data — our team returns a risk assessment summary, air termination or earthing layout, bill of materials and a fixed-price proposal.
- Risk assessment to IS/IEC 62305-2
- IEC 62561 type-tested ARK Make components
- Direct instant response on WhatsApp