Lightning Protection Adequacy Study

Lightning Protection Adequacy Study

Lightning Protection Adequacy Study Services by DFMHUB

Lightning Protection Adequacy Study (LPAS) – Expert Evaluation by DFMHUB

A Lightning Protection Adequacy Study is a critical engineering assessment to verify whether an existing lightning protection and earthing system is safe, compliant, and sufficient for protecting people, structures, and sensitive electrical/electronic equipment.

DFMHUB offers professional Lightning Protection Adequacy Study services across India, designed for industrial plants, commercial buildings, data centers, solar power plants, oil & gas facilities, telecom towers, hospitals, and high-rise structures.

Our study aligns with IEC 62305, IS/IEC standards, NBC of India, and insurance audit requirements.


What Is a Lightning Protection Adequacy Study?

A Lightning Protection Adequacy Study evaluates:

  • The risk of lightning strikes

  • The effectiveness of existing lightning arrestors

  • The integrity of down conductors and bonding

  • The performance of earthing systems

  • The need for upgradation or redesign

The objective is to ensure that your facility is adequately protected against direct strikes, side flashes, step & touch potentials, and surge-induced damages.


Scope of Lightning Protection Adequacy Study by DFMHUB

1. Site Survey & Data Collection
  • Building layout & height analysis

  • Occupancy type & risk category

  • Soil resistivity & environmental conditions

  • Review of existing drawings & reports

2. Lightning Risk Assessment (IEC 62305)

  • Risk of loss of human life

  • Risk of service interruption

  • Risk of cultural or economic loss

  • Determination of Lightning Protection Level (LPL I–IV)

3. External Lightning Protection Evaluation

  • Air terminals / lightning arrestors adequacy

  • Placement as per rolling sphere & protection angle method

  • Down conductor routing & spacing

  • Mechanical & corrosion condition

4. Earthing & Bonding Assessment

  • Earth resistance testing (Ohmic values)

  • Continuity testing of down conductors

  • Equipotential bonding verification

  • Separation distance compliance

5. Surge Protection System Review

  • SPD type & coordination (Type 1, 2, 3)

  • Protection of power, data & control lines

  • Panel-level surge mitigation


Deliverables – What You Get

✔ Detailed Lightning Protection Adequacy Report
✔ Compliance check with IEC 62305 / IS standards
✔ Risk calculation & protection level justification
✔ Deficiency list with photographic evidence
✔ Clear recommendations for upgradation
✔ Bill of quantities (BOQ) for corrective actions
✔ Support for insurance & statutory audits


Applications & Industries We Serve

  • Industrial manufacturing plants

  • Commercial & IT buildings

  • Data centers & telecom infrastructure

  • Solar & wind power projects

  • Oil & gas installations

  • Hospitals & healthcare facilities

  • Airports, metros & public infrastructure


Why Choose DFMHUB for Lightning Protection Adequacy Study?

  • ✅ Experienced lightning protection engineers

  • ✅ IEC 62305 & NBC-compliant methodology

  • ✅ Independent & unbiased technical evaluation

  • ✅ Pan-India service capability

  • ✅ Trusted by EPC contractors & consultants

  • ✅ Practical, cost-optimized recommendations


When Is a Lightning Protection Adequacy Study Required?

  • Before insurance renewal or claim validation

  • After lightning-related incidents or failures

  • During plant expansion or building modification

  • For old or undocumented LPS installations

  • For regulatory or safety audits


FAQs – Lightning Protection Adequacy Study

Is Lightning Protection Adequacy Study mandatory?

While not always mandatory, it is often required for insurance approvals, statutory audits, and critical infrastructure projects.

How often should an adequacy study be conducted?

Recommended every 2–3 years or after any major modification, lightning event, or equipment failure.

Do you provide redesign solutions if the system is inadequate?

Yes. DFMHUB provides design upgrades, BOQ, and execution support if improvements are required.

Which standards do you follow?

We strictly follow IEC 62305, IS standards, and National Building Code (NBC) of India.

Do you cover earthing system testing as part of the study?

Yes. Earthing resistance, continuity, and bonding checks are an integral part of our adequacy study.


Contact DFMHUB – Lightning Protection Experts

Protect your facility before lightning becomes a liability.

📞 Request a Lightning Protection Adequacy Study
📧 Get a detailed proposal & compliance report
📍 Serving industries and infrastructure projects across Indi