Trusted experts in Earthing and Lightning Protection Systems since 2005.
Pune is one of India’s fastest-growing industrial and infrastructure hubs, with increasing demand for electrically safe, code-compliant grounding solutions. As a leading Structural Earthing System Manufacturer in Pune, ARK Make by DFMHUB designs and manufactures foundation-based earthing systems engineered for rocky soil conditions, high fault currents, and monsoon climate variations commonly found across Maharashtra and Western India.
Unlike conventional pipe or chemical earthing, our structural earthing systems in Pune integrate directly with RCC foundations, ensuring long-term earth resistance stability, full compliance with IS 3043 and IEC standards, and reliable performance for industrial plants, data centers, commercial buildings, and infrastructure projects across Pune, Pimpri-Chinchwad, Chakan, and MIDC regions.
A Structural Earthing System is a foundation-based earthing method where earthing conductors are permanently bonded to RCC reinforcement steel, creating a large-area, low-impedance earthing electrode embedded within the building structure itself.
The ARK Make system by DFMHUB enhances this concept using engineered copper-bonded conductors, tested clamps, and documented bonding methodology.
Pune is one of India’s fastest-growing industrial and infrastructure hubs, with increasing demand for electrically safe, code-compliant grounding solutions. As a trusted Structural Earthing System Manufacturer in Pune, ARK Make by DFMHUB designs and manufactures foundation-based earthing systems engineered specifically for rocky soil conditions, high fault currents, and monsoon climate variations commonly found across Pune, Pimpri-Chinchwad, Chakan, and MIDC regions of Maharashtra.
Conventional pipe or chemical earthing systems in Pune often fail within 2–5 years due to:
High soil resistivity (often exceeding 1000 Ω·m)
Seasonal moisture fluctuation
Limited space in urban & industrial plots
Poor long-term compliance with IS 3043
Structural earthing eliminates these risks by converting the RCC foundation itself into a permanent, low-impedance earth electrode system.
Large parts of Pune and surrounding MIDC zones sit on basalt rock and hard strata, making conventional earth pits ineffective or inconsistent.
Chemical and pipe earthing systems show wide resistance variation between summer and monsoon seasons, leading to unsafe fault clearance.
With increasing data centers, EV infrastructure, automation, and high-load industrial plants, Pune projects demand stable earthing below 1Ω—achievable only through structural earthing.
ARK Make systems are engineered and manufactured in Pune, ensuring faster customization and compliance with Indian construction practices.
RCC foundation earthing design
Lightning & fault current analysis
Coordination with EPCs & consultants
MIDC Chakan, Talegaon, Ranjangaon
IT Parks & Data Centers
Hospitals & Infrastructure Projects
The entire RCC foundation acts as a distributed earthing electrode.
All reinforcement is electrically bonded using copper or GI bonding clamps to ensure continuity.
Structural earthing forms the termination network for IEC 62305 compliant lightning protection systems.
| Component | Material | Function |
|---|---|---|
| Copper Bonded Conductor | 10mm Copper Coated | Primary current dissipation |
| Rebar Bonding Clamp | SS/GI | Electrical continuity with RCC |
| Earth Fixed Point | SS/GI | External testing & inspection |
| Cross and Parallel Connector | SS/GI | Mechanical fixing |
| Strip Holder / Saddle | SS/ GI | Mechanical fixing |
| Equipotential Bonding Bar | SS/CU | External testing & inspection |
Step 1: Soil & Site Assessment
Step 2: Building Load Evaluation
Step 3: Earthing Network Design
Step 4: Resistance Targeting
Step 5: Documentation & As-Built Drawings
| Standard / Regulation | Applicability |
|---|---|
| IS 3043:2018 | Code of Practice for Earthing |
| CEA Safety Regulations | Mandatory for electrical systems |
| NBC of India | Building safety compliance |
| IEC 62305 | Lightning protection interface |
Wenner 4-point method
Multi-depth testing
Seasonal correction factors
Industrial plants: ≤1Ω
Data centers & substations: ≤0.5Ω
Critical infrastructure: ≤0.25Ω
Fault current: up to 50 kA
Lightning impulse: up to 200 kA
| Standard | Applicability |
|---|---|
| IS 3043:2018 | Earthing system design |
| IEC 62305 | Lightning protection |
| CEA Regulations | Electrical safety |
| NBC 2016 | Building compliance |
| MNRE | Solar & renewable |
| Aspect | ARK Make Manufacturer | Local Trader |
|---|---|---|
| Engineering Design | ✔ Yes | ✖ No |
| IS Compliance | ✔ Documented | ✖ Unverified |
| Customization | ✔ Project-specific | ✖ Generic |
| Accountability | ✔ Single source | ✖ Fragmented |
Design calculations & GA drawings
On-site supervision across Pune & Maharashtra
Earth resistance testing & commissioning
As-built drawings & O&M manuals.