Trusted experts in Earthing and Lightning Protection Systems since 2005.
Electrical safety failures in buildings are not caused by equipment alone — over 65% of electrical faults in India are directly linked to inadequate earthing and grounding systems (CEA safety audit observations, 2023).
In a country with high soil resistivity variation, dense urban construction, monsoon-driven moisture cycles, and rapidly increasing electrical loads, conventional pit earthing methods are no longer sufficient.
The ARK Make Structural Earthing System by DFMHUB is engineered as a permanent, foundation-integrated earthing solution, designed specifically for Indian soil conditions, RCC structures, and statutory compliance requirements.
A Structural Earthing System is a foundation-based earthing method where earthing conductors are permanently bonded to RCC reinforcement steel, creating a large-area, low-impedance earthing electrode embedded within the building structure itself.
The ARK Make system by DFMHUB enhances this concept using engineered copper-bonded conductors, tested clamps, and documented bonding methodology.
The ARK Structural Earthing System is not a single product — it is a coordinated system consisting of conductors, bonding components, test points, and documentation. System Architecture Flow:
| Component | Material | Function |
|---|---|---|
| Copper Bonded Conductor | 10mm Copper Coated | Primary current dissipation |
| Rebar Bonding Clamp | SS/GI | Electrical continuity with RCC |
| Earth Fixed Point | SS/GI | External testing & inspection |
| Cross and Parallel Connector | SS/GI | Mechanical fixing |
| Strip Holder / Saddle | SS/ GI | Mechanical fixing |
| Equipotential Bonding Bar | SS/CU | External testing & inspection |
Step 1: Soil & Site Assessment
Step 2: Building Load Evaluation
Step 3: Earthing Network Design
Step 4: Resistance Targeting
Step 5: Documentation & As-Built Drawings
| Standard / Regulation | Applicability |
|---|---|
| IS 3043:2018 | Code of Practice for Earthing |
| CEA Safety Regulations | Mandatory for electrical systems |
| NBC of India | Building safety compliance |
| IEC 62305 | Lightning protection interface |
| Industry | Use Case |
|---|---|
| High-rise Residential | Lift & DG safety |
| Commercial Buildings | Fire & surge protection |
| Data Centers | Sensitive equipment grounding |
| Hospitals | Patient safety |
| Substations | Fault current dissipation |
| Solar Power Plants | Inverter & array grounding |
| Industrial Plants | Motor & PLC protection |
| Aspect | Manufacturer (DFMHUB) | Trader |
|---|---|---|
| Design Support | ✔ Engineering-backed | ❌ None |
| Material Traceability | ✔ Full | ❌ Limited |
| Compliance Docs | ✔ Provided | ❌ Missing |
| Customization | ✔ Project-specific | ❌ Generic |
| Accountability | ✔ Single-point | ❌ Fragmented |