Lightning Protection
ARK-PH08IN STOCK

IS 3043 / IEC 62305
Direct OEM Supply
Pan-India Dispatch
100% Inspected
Brand: ARKDown Conductor Support
Parapet Holder Clamp
Engineered Lightning & Earthing Component
Manufactured to strict industrial standards for commercial, solar EPC, substation, and industrial infrastructure installations.
Manufacturer
ARK / DFMHUB
Product Code
ARK-PH08
Application
Down Conductor Support
Compliance
IS 3043 & IEC 62305
Product Description & Engineering Scope
Detailed technical specifications, material performance & installation guidelines
Nylon Parapet Conductor Clamp /Parapet Holder Clamp (ARK-PH08) is an ARK external lightning protection component manufactured by DFMHUB in India. It retains a round lightning conductor along parapet surfaces while keeping the route orderly and accessible for inspection. The product is intended for engineered lightning protection installations on commercial, industrial, residential, infrastructure, data-centre and solar projects. It gives procurement and site teams a defined catalogue item instead of an improvised site-made part.
A conductor fastener is a safety-relevant part of the installed system because poor restraint can change conductor routing, stress a joint or make inspection difficult. The holder must match the conductor, roof or wall interface and exposure conditions. The fixing to the building fabric must also be engineered for the actual substrate; component compliance alone does not validate an unsuitable anchor or roof detail.
DFMHUB supports the ARK range as a manufacturer, with controlled drawings, repeatable fabrication or assembly, dimensional checks and project-specific technical coordination. Material grade, dimensions, finish, fastener configuration and any required test evidence should be frozen in the approved technical submittal before production. This approach helps consultants, EPC teams and contractors compare the offered component with the BOQ, installation detail and environmental exposure rather than relying only on a product name.
Technical Specifications • Neat support for exposed parapet routes • Non-metallic body helps separate conductor from the mounting surface • Simple inspection of conductor seating • Repeatable mounting across long roof perimeters
During installation, keep the conductor seated without damaging its surface, maintain the route shown on the approved drawing and use the specified anchors and torque. Coordinate penetrations with waterproofing requirements. The completed route should remain visible and accessible for periodic inspection, especially after roof work or severe weather.
Selection note: Verify conductor diameter, parapet material, anchor type, exposure conditions, fixing interval and movement allowance before installation. The applicable system layout should be prepared by a competent lightning protection designer and coordinated with the structure, roof system, services and earthing network.
For quotations, submit the product code ARK-PH08, required quantity, conductor or interface dimensions, material preference, project location and approved drawing. DFMHUB can then align manufacture, inspection records, packing and delivery with the project requirement.
A conductor fastener is a safety-relevant part of the installed system because poor restraint can change conductor routing, stress a joint or make inspection difficult. The holder must match the conductor, roof or wall interface and exposure conditions. The fixing to the building fabric must also be engineered for the actual substrate; component compliance alone does not validate an unsuitable anchor or roof detail.
DFMHUB supports the ARK range as a manufacturer, with controlled drawings, repeatable fabrication or assembly, dimensional checks and project-specific technical coordination. Material grade, dimensions, finish, fastener configuration and any required test evidence should be frozen in the approved technical submittal before production. This approach helps consultants, EPC teams and contractors compare the offered component with the BOQ, installation detail and environmental exposure rather than relying only on a product name.
Technical Specifications • Neat support for exposed parapet routes • Non-metallic body helps separate conductor from the mounting surface • Simple inspection of conductor seating • Repeatable mounting across long roof perimeters
During installation, keep the conductor seated without damaging its surface, maintain the route shown on the approved drawing and use the specified anchors and torque. Coordinate penetrations with waterproofing requirements. The completed route should remain visible and accessible for periodic inspection, especially after roof work or severe weather.
Selection note: Verify conductor diameter, parapet material, anchor type, exposure conditions, fixing interval and movement allowance before installation. The applicable system layout should be prepared by a competent lightning protection designer and coordinated with the structure, roof system, services and earthing network.
For quotations, submit the product code ARK-PH08, required quantity, conductor or interface dimensions, material preference, project location and approved drawing. DFMHUB can then align manufacture, inspection records, packing and delivery with the project requirement.
Technical Specifications
Exact material properties and physical parameters
| Material | Nylon PA6 |
| Height | 52mm |
| Rod Diameter | 8mm |
Key Features & Engineering Advantages
Why EPC contractors and MEP consultants standardize on ARK Make
- IEC 62561-4:2023 (conductor fasteners); system design to IEC 62305-3:2024
Recommended Applications
Approved project sectors and installation environments
- Intended for nominal 8 mm round conductor; confirm final fit against the approved drawing
Frequently Asked Questions
Common technical queries and installation guidance